54.9-C.    Conductor Material

 

All conductors of a rack group in the same vertical plane shall be of the same material.

 

(1)    Urban Districts: Conductors in rack construction in urban districts shall have a crossing not less than the equivalent of double braid weather-resistant covering.

 

(2)    Rural Districts: Line conductors in rack construction in rural districts may be bare conductors provided the vertical separation between conductors is not less than 12 inches and conforms to the requirements of Rule 54.9-D where greater separation is specified.

 

Strikeout and Underline Versions

Rule 54.9-C

 

54.9-C.    Conductor Material

 

All conductors of a rack group in the same vertical plane shall be of the same material.

 

(1)    Urban Districts: Conductors in rack construction in urban districts shall have a crossing not less than the equivalent of double braid weather-resistant covering.

 

(2)    Rural Districts: Line conductors in rack construction in rural districts may be bare conductors provided the vertical separation between conductors is not less than 12 inches and conforms to the requirements of Rule 54.9-D where greater separation is specified.

 

NOTE:    Resolution No. E-949 effective February 11, 1957, authorized that the provisions of Rule 54.9-C(1), 54.9-C(2) and 54.9-D shall not be held to apply to the use of 0-750 volt duplex service drop cable consisting of one suitably insulated conductor with a bare neutral conductor as the line conductor between a pole supporting street light circuits and metal and/or concrete electroliers or wood or steel poles where the latter supports street light fixtures.

 

Final Version

Rule 54.9-C

 

 

54.9-C.    Conductor Material

 

All conductors of a rack group in the same vertical plane shall be of the same material.

 

(1)    Urban Districts: Conductors in rack construction in urban districts shall have a crossing not less than the equivalent of double braid weather-resistant covering.

 

(2)    Rural Districts: Line conductors in rack construction in rural districts may be bare conductors provided the vertical separation between conductors is not less than 12 inches and conforms to the requirements of Rule 54.9-D where greater separation is specified.

 

NOTE:    Resolution No. E-949 effective February 11, 1957, authorized that the provisions of Rule54.9-C(1), 54.9-C(2) and 54.9-D shall not be held to apply to the use of 0-750 volt duplex service drop cable consisting of one suitably insulated conductor with a bare neutral conductor as the line conductor between a pole supporting street light circuits and metal and/or concrete electroliers or wood or steel poles where the latter supports street light fixtures.